Call Us Toll Free (888) 2-VOLGEN
SEARCH:

KTPS90 --- 90 Watt

KTPS90 is a 90 WATT, Universal Input Desktop Type Adapter

Features

  • 90 WATT OUTPUT POWER
  • SINGLE OUTPUT TO 90W
  • UNIVERSAL INPUT
  • CEC LEVEL V
  • REGULATED OUTPUT WITH LOW RIPPLE NOIOSE
  • COMPACT, LOW-PROFILE PACKAGES
  • MODIFIED AND CUSTOM DESIGNS AVAILABLE

 

Model Output Voltage Output Current Output Power
KTPS90-1207
12VDC 7.00A 84W
KTPS90-1506
15VDC 6.00A 90W
KTPS90-1656 16VDC 5.60A 90W
KTPS90-1805
18VDC 5.00A 90W
KTPS90-1947
19VDC 4.74A 90W
KTPS90-2045 20VDC 4.50A 90W
KTPS90-2437 24VDC 3.75A 90W
KTPS90 --- 90 Watt

Electrical Specifications

All specifications are typical at nominal input, full load

Input Specifications

Input Voltage100 ~ 240VAC
Input Frequency50 ~ 60Hz
Input Current1.2A Max
ProtectionInternal primary Current Fuse
Inrush Limiting
ConfigurationIEC320/C6

Output Specifications

Output VoltageSee Above
Ripple and Noise1 - 2% Vp-p Max for Output Voltage @ Full Load
Transient Response0.5mS for 50% Load Change Typical
Load Regulation±5% Typical
Hold-Up Time10mS @ Full Load
ProtectionShort Circuit Protection
Over Voltage Protection
Over Current Protection
DC Cord18 AWG (16 AWG / 14 AWG Optional)
2.5 x 5.5 x 9.5mm C+ Connector
Ferrite CoreYes

General Specifications

Dielectric Withstand3000VAC Primary - Secondary
Leakage Current3.5mA @ 3pin
EMI Conduction & RadiationCompliance to EN55022 Class B
Harmonic CurrentCompliance to EN61000-3-2,3
EMS ImmunityCompliance to
EN61000-4-2,3,4,5,6,8,11
MTBF50,000 Calculated Hours by 25°C, by MIL-HDBK-217F
TopologySwitching Flyback
EfficiencyMeet Energy Star Level V & ERP Stage 2

Environmental Specifications

Operating Temperature0°C ~ +40°C
Storage Temperature-20°C ~ +80°C
Operating Humidity20 ~ 80% Rh
Storage Humidity10 ~ 90% Rh
CoolingConvection

Physical Specifications

Case Dimensions139 x 61 x 36 mm (L x W x H)
Weight415g

Safeties/Approvals

Safeties/ApprovalsUL, cUL, CE, CB, GS, PSE, FCC